Showing results: 1 - 15 of 35 items found.
-
Radiometrics Midwest Corporation
One of the more difficult tests to understand is shielding effectiveness or transfer impedance. The data from these tests may vary dramatically based on the test method selected, test fixture, test setup, measurement sensitivity, test personnel, etc. At Radiometrics all shielding effectiveness test are performed or supervised by NARTE Certified engineers.
-
Keystone Compliance
Shielding effectiveness testing determines the ability of material to reduce the electromagnetic field in a space by blocking the field with barriers made of conductive and/or magnetic materials. Shielding effectiveness testing can be applied to a broad range of radio frequencies. Electromagnetic Shielding is typically applied to both enclosures and cables. The shielding can reduce the coupling or radio waves, electromagnetic fields and electrostatic fields. The amount of reduction can vary based on the material used, its thickness, the size of the shielded volume and the frequency of the fields of interest. Also impacting the effectiveness of the shielding is the size, shape and orientation or apertures in a shield to an incident electromagnetic field. Electromagnetic shielding that blocks radio frequency electromagnetic radiation is also known as RF Shielding.
-
EM-2107A | 30 MHz – 1.5 GHz -
Electro-Metrics Corp.
The EM-2107A is a standard test fixture for evaluation of the electromagnetic shielding effectiveness of planar material. The fixture is an enlarged section of coaxial transmission line and complies fully with the requirements of ASTM test method D4935-1. The measured data relates to the shielding effectiveness due to a plane wave (far field EM wave) from which near field values for magnetic and electric fields may be inferred. The EM-2107A is provided with a reference standard test specimen, a dynamic range specimen. Dynamic range of greater than 80dB is achievable, although the cables and other test system components usually establishes the limiting factors.
-
EM-2108 | 1.5 GHz – 10 GHz -
Electro-Metrics Corp.
The EM-2108 is a standard test fixture for evaluation of the electromagnetic shielding effectiveness (SE) of planar materials. The fixture is a section of coaxial transmission line broken to allow the insertion of planar test materials. Although ASTM D4935-10 is currently limited to an upper frequency of 1.5 GHz, the EM-2108 meets and complies fully with both the impedance and SE requirements called out in ASTM test method D4935-10 up to 10 GHz. These results are shown in Figures 1 & 2. The measured data relates to the shielding effectiveness due to a plane wave (far field EM wave) from which near field values for magnetic and electric fields may be inferred.
-
Eurofins E&E
Eurofins E&E North America can easily develop sound engineering measurement techniques to quantify the SE of your product. Our process involves creating detailed SE Test Plans used to insure accurate and repeatable test results.Eurofins a has years of experience to assure our customers that the evaluation reflects the electrical attenuation performance of the material. Often times, our test report becomes supporting documentation for our customer’s end-user contractual requirement, where Independent Test Laboratory results verify the electrical performance of the material being tested.
-
QuietBox-100m -
Raymond RF Measurements Corp.
The Raymond RF QuietBox-100m line portable shielded enclosures are made from the same proven modular RF shielding materials as full size Modular RF Shielded Enclosure systems and offer the same exceptional RF Shielding Effectiveness. The QuietBox-100m is the perfect portable tabletop and laboratory enclosure where larger interior volume or higher RF Shielding Effectiveness is required.
-
JRE 2214 -
JRE Test, LLC
Like its other brothers in the JRE test line, it features rugged welded aluminum construction with superb RF shielding effectiveness. Long life door gasket material along with double edge engagement not only provides solid RF shielding, but smooth trouble-free operation over its lifespan. Tough 'honeycomb' vent maintains shielding effectiveness throughout the full frequency range. Optional fan is available for additional airflow.
-
JRE 0814-2R -
JRE Test, LLC
Containing all the capability of the larger JRE enclosures, the rack mounted 0814-2R is ideal for testing devices with a tall form factor. Two independent 0814 series enclosures are mounted in one 19 inch rack. Two shielded vents provide excellent cooling and optional fan(s) are available for those hot products. Tough 'honeycomb' vents maintain shielding effectiveness throughout the frequency range. Featuring rugged welded aluminum construction, you can be assured of its tight RF shielding effectiveness.
-
EM-6874 | 20 Hz – 30 MHz -
Electro-Metrics Corp.
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
JRE 1618 -
JRE Test, LLC
Like its other brothers in the JRE test line, it features rugged welded aluminum construction with superb RF shielding effectiveness. Long life door gasket material along with double edge engagement not only provides solid RF shielding, but smooth trouble-free operation over its lifespan.
-
JRE 0814 -
JRE Test, LLC
Testing tall devices? The 0814 stands up to any test up to 18 GHz! Featuring a wide swing open door with durable latch handle, this enclosure finds wide use in the WiFi test environment. Two shielded vents provide excellent cooling and optional fan(s) are available for those hot products. Tough 'honeycomb' vents maintain shielding effectiveness throughout the frequency range. Featuring rugged welded aluminum construction, you can be assured of its tight RF shielding effectiveness.
-
PAMS & PAMS-C -
Praxsym
PAMS is a user-friendly, transmitter and receiver system that measures shielding effectiveness in RF shielded enclosures. Lightweight and compact, each PAMS unit measures approximately 12” x 5” x 5” and weighs 5.5 lbs., making PAMS ideally suited to field measurement tasks. Rugged construction insures instrument survivability in a field test environment. PAMS-C is a simple and efficient solution for quickly identifying shielding faults in an RF shielded enclosure. Cousin to the original PAMS used extensively by customers operating RF Shielded Enclosures, PAMS-C gives commercial end-users everything needed to measure shielding effectiveness levels of critical infrastructure - all with minimal or no interruption to normal operations.
-
JRE 0814-2R-A -
JRE Test, LLC
Containing all the capability of the larger JRE enclosures, the rack mounted 0814-2R-A is ideal for testing IEEE 802.11 a,b,g devices such as; WLAN, VoIP, access points and other RF devices. Two independent 0814 series enclosures are mounted in one 19 inch rack. Two shielded vents provide excellent cooling and optional fan(s) are available for those hot products. Tough 'honeycomb' vents maintain shielding effectiveness throughout the frequency range. Featuring rugged welded aluminum construction, you can be assured of its tight RF shielding effectiveness.
-
A.H.Systems, Inc.
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
JRE 2218 -
JRE Test, LLC
Breeze through laptop RFI and wireless tests with the 'bigger than-a-breadbox' 2218! Like its other brothers in the JRE test line, it features rugged welded aluminum construction with superb RF shielding effectiveness. Long life door gasket material along with double edge engagement not only provides solid RF shielding, but smooth trouble-free operation over its lifespan.